  components measuring instruments improved for even faster and more efficient measurements ! minimum measurement time of 5 ms, built-in comparator and 0.08% measurement accuracy 2001 hioki company overview, new products, environmental considerations and other information are available on our website. http://www.hioki.co.jp/ iso14001 jqa-e-90091 3511-50 lcr hitester the 3511-50 lcr hitester features both high performance, highspeed measurements with a low prices. the minimum measurement time of 5 ms and basic accuracy of 0.08% makes the instrument suitable for use on production lines and laboratories. the built-in high- speed comparator significantly reduces production line tact time and allows the construction of automatic production lines. the very compact body features a clearly visible led display that facilitates easy operation and allows settings to be confirmed at a glance. with its high-speed measurement, highly accurate measurement capabilities and great cost performance, this lcr measurement instrument is bound to satisfy the needs of a variety of users. improved with faster measurement !
ext. i/o signals comparator function upper limit and lower limit values can be set for both the main parameters (any of z or c or l or r) and sub- parameters (any of or d or q). the measurement results are signaled by a buzzer and led indication and can also be output to an external source. the output is separated into main- and sub-parameter measurement results together with and. memory for 99 sets of measurement conditions up to 99 sets of measurement conditions, including comparator values, provide rapid response to constantly changing components on flexible production lines. these conditions can also be externally switched via the ext.i/o. compact size the small dimensions, 210 (w) 100 (h) 168 (d) mm, approximately 2.5 kg (4.00"w 8.30"h 6.60"d; 88 oz. approx.), make it easy to incorporate the instrument into production lines. 1 better speed, better accuracy rs-232c interface the ac power supply voltage is selectable : 100 v, 120 v, 220 v or 240 v ac. ext.i/o rear view outputs ?internal dc power (+5 v output) ?comparator result (main-/sub- parameters together with and output) ?analog measurement completion ?end-of-measurement the following chart shows the timing sequence of the trigger (trig), and end-of-measurement (eom) signals from the ext. i/o connector. trig chuck on eom hi in lo trigger minimum interval 100 s 500 s circuit response time * 1 measurement time 5 ms * 2 decision result chuck off *1 depends on the sample and trigger delay. *2 reference value for 1 khz measurement frequency, fast mode, |z| measurement. measurement time differs with measurement conditions. 9518-01 gp-ib interface can be fitted (optional). inputs ?external dc power supply (+5 v to +24 v can be supplied by external device) ?external trigger signal ?memory setting selection (including comparator conditions) minimum measurement time of 5 ms three sampling rates can be selected: fast, normal and slow. the minimum measurement time of 5 ms (with 1 khz/|z| display) gives rapid sampling for improved production line efficiency. (differs with the measurement frequency and display parameters.) high resolution and high measurement accuracy the measurement resolution provides a full five digits, and the basic measurement accuracy is 0.08%. rs-232c interface as standard feature with the exception of turning the power on or off, all the basic functions can be controlled from a pc. use of a pc enables efficient data management, processing, and setting of measurement conditions, plus a variety of other functions. a gp-ib interface can also be installed as an option. ext.i/o trigger signals, recording on/off, and loading of measurement conditions can be externally controlled. complete interface allows the unit to be used as an automatic instrument where comparator results, measurement-completed signals, etc., can be output to an external device. rs-232c interface specifications transmission method: start-stop synchronization. transmission speed: 9600 bps. data length: 8 bits. parity: none. stop bit: 1 bit. delimiter: cr+lf. handshake: hardware. connector shape: d-sub 9pin (male). connecting cable: reverse cable powerful functions for greater line efficiency timing chart for ext. i/o sequencing
measurement parameters |z|, c, l, r, , d, q * five possible display combinations: |z|- , c-d, l-d, l-q, r. measurement frequency (0.01%) 120 hz basic accuracy output impedance - 90.00? to +90.00? equivalent circuit mode l 14.00 h 200.00 kh display method/max. count no. of measurement condition memory retention max. 99 (including comparator conditions) comparator comparison method any of the main parameters (any of |z| or c or l or r) and sub-parameters (any of or d or q) can be set to upper limit and lower limit value settings. the measurement results are signaled by led indication and a buzzer and ext.i/o output (main- and sub-parameter evaluation results, and output). dc bias possible when the optional 9268 (40 v max.) or 9269 (2 a max.) is used. external printer 9442 printer (option) external interfaces rs-232c, (gp-ib is option), ext.i/o for sequence use. c 9.40 pf to 999.99 mf q 0.85 to 999.99 measurement signal levels 50 mv/500 mv/1 v rms (10% 5 mv) specifications measurement range (auto/hold range, 5-digit display) |z|, r : 100 m/1/10/100/1 k/10 k/100 k/1 m/ 10 m/200 m ? c (120 hz) : 145 p/1.45 n/14.5 n/145 n/1.45 /14.5 / 145 /1.45 m/14.5 m/1 f c (1 khz) : 17 p/170 p/1.7 n/17 n/170 n/1.7 /17 / 170 /1.7 m/100 mf l (120 hz) : 130 /1.3 m/13 m/130 m/1.3/13/130/ 1.3 k/13 k/200 kh l (1 khz) : 15.5 /155 /1.55 m/15.5 m/155 m/1.55/ 15.5/155/1.55 k/20 kh dimensions, mass : 210h 100w 168d mm, 2.5 kg approx. (8.30"h 4.00"w 6.60"d ; 88 oz. approx.) power supply : 100 v/120 v/220 v/ 240 v ac 10% (selectable), 50/60 hz max. rated power : 20 va max. supplied accessories : power cord, spare fuse for power supply (in accordance with the ordered power specifications, either 100/120 vac 1 a, 220/240 vac 0.5 a) conformity : emc en61326-1:1997+a1:1998 en61000-3-2:1995+a1:1998+a2:1998 en61000-3-3:1995 safety en61010-1:1993+a2:1995 power supply; pollution degree 2 overvoltage category ii (anticipated transient overvoltage 2500 v) test terminals; pollution degree 2 overvoltage category i (anticipated transient overvoltage 330 v) measurement ranges 10 m ? to 200.00 m ? 1 khz z : 0.08% rdg. 0.05? serial- and parallel equivalent circuit mode, automatic/manual 50 ? led (5-digit display, full-scale count depends on range) d 0.0001 to 1.9900 fast : 5 ms, normal : 60 ms, slow : 300 ms measurement time (typical values for displaying |z|) excluding time for open/short circuit compensation, evaluation. fast : 13 ms, normal : 80 ms, slow : 400 ms ... and better size ! seven parameters measured the seven parameters |z|, r, , c, l, d, and q can be measured. the main- and sub-displays can be combined in five ways: |z|- , c-d, l-d, l-q, r. easy operation by simple selections and led display to operate, simply select from the items displayed on the panel. selected measurement conditions are indicated by illuminated leds allowing settings to be checked at a glance. measurement results are also displayed by led indication that makes it easy to check the values even in dark locations. dc bias measurement using the optional 9268/9269 dc bias unit, voltage and current bias measurements are simple. the 9268 can be used for voltages up to a maximum of dc40 v. the 9269 can be used for currents up to a maximum of dc2 a. measurement signals measurement frequency: 120 hz/1 khz. signal level: 50 mv, 500 mv, 1 vrms settable. printer output measurement values and comparator results can be printed out on the optional 9442 printer by connecting this via the standard rs-232c interface. this is convenient for attaching data to inspection reports, etc. (the optional 9444 connection cable and ac adapter are necessary for connecting the printer.) example of connecting the 9262 and 9268 / 9269 |z| , r 2 basic performance printout example resulting measurement data can be output not only to a printer, but also other media such as a pc or sequencer. using the rs-232c interface makes transferring the inspection data simple and convenient. 9442 printer specifications printing method : thermal serial dot printer recording width : 112 mm (4.41? printing speed : 52.5 cps power supply : 9443 ac adapter or supplied ni-mh battery pack (prints 3000 lines on full charge from 9443 ac adapter) dimensions and mass : 160w 66.5h 170d mm; 580 g approx. (6.30"w 2.62"h 6.70"d; 20.46 oz. approx. ) 0.940 pf to 99.999 mf 1.600 h 20.000 kh
3511-50 lcr hitester [standard accessories: power cord, spare power fuse (1 a for 100/120 v ac rating, 0.5 a for 220/240 vac rating) ] options for a wide range of applications 9140 four-terminal probe dc to 100 khz 9143 pincher probe dc to 5 mhz 9261 test fixture dc to 5 mhz 9262 test fixture dc to 5 mhz * all cable lengths are 1 m (39.37?. 9263 smd test fixture dc to 5 mhz 9268 dc bias voltage unit maximum applied voltage: 40 v dc 9269 dc bias current unit maximum applied current: 2 a dc conditions of guaranteed accuracy : temperature and humidity 23 ? c5 ? c (73 ? f9 ? f), less than 80% rh (no condensation), following 60 min. warm-up after power is turned on, after open/shut calibration, use of 9261 test fixture, measurement signal level 1 vrms, measurement speed set to slow. the various accuracy specifications presume that < 6?c for r, d 0.1 for c-d, d 0.1 for l-d, q 10 for l-q. q accuracy is defined by the calculation of 1/d. measurement range and accuracy differ with the used test fixture, measurement signal level and measurement speed. *z l is the sample impedance [ ? ], z h is the sample impedance [m ? ], r l is the sample resistance [ ? ], r h is the sample resistance [m ? ], c h is the sample capacitance [mf], c l is the sample capacitance [pf], l l is the sample inductance [h], l h is the sample inductance [kh], and f is the measurement frequency [khz]. ( |z|, r, c, l : %rdg.) 9165 connection cord (for 9268/9269; bnc to bnc; 1.5 m/59.05? 9166 connection cord (for 9268/9269; bnc to clips; 1.5 m/59.05? 9518-01 gp-ib interface 9151-02 gp-ib connection cable (2 m/78.74? 9151-04 gp-ib connection cable (4 m/157.48? 9442 printer 9443-01 ac adapter (for 9442, japan) 9443-02 ac adapter (for 9442, eu) 9443-03 ac adapter (for 9442, usa) 9444 connection cable (for 9442 / 1.5 m/59.05? 1196 recording paper (for 9442 / 25 m/984.25? 10 rolls) test fixtures are not supplied with the unit. select an optional test fixture when ordering. options 9140 four-terminal probe 9143 pincher probe 9261 test fixture 9262 test fixture (direct connection type) 9263 smd test fixture (direct connection type) 9268 dc bias voltage unit 9269 dc bias current unit measurement accuracy and range frequency (|z|- and r have common frequency) i z i 120 hz 1 khz c-d c d 120 hz 1 khz l-d l d 100 m ? (1.00+0.15/z l )% (0.10+0.09/z l ) ? 1 f 100 mf (0.60+1.50 ? f ? c h )% (0.0015+0.0108 ? f ? c h ) 130 h 15.5 h {0.90+30/(f ? l l )}% {0.0021+0.264/(f ? l l )} range 1 k ? 0.08% 0.05? 14.5 f 1.7 f 0.09% 0.0011 1.3 h 155 mh 0.09% 0.0011 10 ? 0.35% 0.18? 1.45 mf 170 f 0.39% 0.0034 13 mh 1.55 mh 0.39% 0.0034 100 k ? 0.14% 0.10? 145 nf 17 nf 0.16% 0.0020 130 h 15.5 h 0.16% 0.0020 1 ? 1.80% 1.00? 14.5 mf 1.7 mf 2.10% 0.0179 1.3 mh 155 h 2.10% 0.0179 100 ? 0.08% 0.08? 145 f 17 f 0.10% 0.0016 130 mh 15.5 mh 0.10% 0.0016 10 k ? 0.11% 0.08? 1.45 f 170 nf 0.13% 0.0016 13 h 1.55 h 0.13% 0.0016 1 m ? 0.30% 0.19? 14.5 nf 1.7 nf 0.34% 0.0036 1.3 kh 155 h 0.34% 0.0036 10 m ? (0.15+0.16 ? z h )% (0.10+0.09 ? z h ) ? 1.45 nf 170 pf {0.17+30/(f ? c l )}% {0.0020+0.264/(f ? c l )} 13 kh 1.55 kh (0.17+1.17 ? f ? l h )% (0.0020+0.0110 ? f ? l h ) 200 m ? (2.00+0.11 ? z h )% (0.70+0.08 ? z h ) ? 145 pf 20 pf {1.70+30/(f ? c l )}% {0.0120+0.25/(f ? c l )} 200 kh 20 kh (2.00+1.00 ? f ? l h )% (0.0120+0.0100 ? f ? l h ) r- (1.00+0.21/r l )% 0.09% 0.39% 0.16% 2.10% 0.10% 0.13% 0.34% (0.15+0.20 ? r h )% (2.00+0.16 ? r h )% i z i - 3511-50e1-17m-05p printed in japan all information correct as of jul. 19, 2001. all specifications are subject to change without notice. head office : 81 koizumi, ueda, nagano, 386-1192, japan tel +81-268-28-0562 / fax +81-268-28-0568 e-mail: os-com@ hioki.co.jp hioki usa corporation : 6 corporate drive, cranbury, nj 08512 usa tel +1-609-409-9109 / fax +1-609-409-9108 e-mail: hioki@ hiokiusa.com distributed by shanghai representative office : 1108 union building, 100 yan an road (east), shanghai, 200002, p.r.china tel +86-21-6328-9947/4938 fax +86-21-6328-2064 e-mail: hioki-sh@sh.cngb.com europe representative office : meineckestrasse 48, 40474 dusseldorf, germany tel / fax +49-221-4544153 e-mail: hioki-eu@ doitsu.de 3 9443-02 9443-01